Loading...
Reading-in archives
Use interface V24 if you want to read in archives. They are transferred and then subsequently
unzipped.
Note
Reading in commissioning archives
When you read in a commissioning archive via the V24 interface, then this is immediately
activated.
Externally processing the punched tape format
If you wish to externally process an archive, then generate this in the punched tape format.
Procedure
...
1. Select the "Program manager" operating area, and press the "NC"
or "Local. drive" softkey.
- OR -
Select the "Startup" operating area and press the "System data"
softkey.
Reading-out archives
2. Select the directories or the files that you wish to send to V24.
3. Press the ">>" and "Archive" softkeys.
4. Press the "V24 send" softkey.
- OR -
Managing programs
14.19 RS-232-C
Turning
Operating Manual, 06/2019, A5E44903486B AB 831