YASKAWA TM.V1000.01 V1000 Drive Installation & Start-Up Manual (Preliminary 01-19-07) 453
DC Bus Overvoltage . . . . . . . . . . . . . . . . . . . . . . . . . 233
DC Bus Undervoltage . . . . . . . . . . . . . . . . . . . 222
, 374
DC Bus Voltage . . . . . . . . . . . . . . . . . . . . . . . . 151
, 409
DC Bus Voltage at Previous Fault . . . . . . . . . . 152
, 412
DC Injection Braking. . . . . . . . . . . . . . . . . . . . . . . . . 256
DC Injection Braking at start . . . . . . . . . . . . . . . . . . . 259
DC Injection Braking at Stop. . . . . . . . . . . . . . . . . . . 258
DC Injection Braking Command . . . . . . . . . . . . . . . . 372
DC Injection Braking Current . . . . . . . . . . . . . 258
, 337
DC Injection Braking Current 2. . . . . . . . . . . . . . . . . 337
DC Injection Braking Start Frequency . . . . . . . . . . . 337
DC Injection Braking Time/DC Excitation Time at
Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337
DC Injection Braking to Stop . . . . . . . . . . . . . . . . . . 138
DC Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
Deceleration Rate Calculation Gain . . . . . . . . . . . . . 387
Deceleration Takes Too Long With Dynamic Braking
Enabled . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
Deceleration Time 1. . . . . . . . . . . . . . . . . . . . . 141
, 344
Deceleration Time 2. . . . . . . . . . . . . . . . . . . . . . . . . . 344
Deceleration Time 3 (Motor 2 Decel Time 1) . 344
, 345
Deceleration Time 4. . . . . . . . . . . . . . . . . . . . . . . . . . 345
Deceleration Time at Stall Prevention during
Acceleration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 387
Default Settings Determined by Drive Capacity
(o2-04) . . . . . . . . . . . . . . . . . .421
, 422, 423, 424, 425
Derated Torque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
Derivative Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 340
dEv . . . . . . . . . . . . . . . . . . . . . . . . . 197
, 199, 206, 226
Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 319
Differential PID Feedback . . . . . . . . . . . . . . . . . . . . . 378
Digital Operator Connection Fault . . . . . . . . . . . . . . 217
Digital Operator Display Selection . . . . . . . . . . . . . . 400
Digital Outputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
DIN Rail Mountable . . . . . . . . . . . . . . . . . . . . . . . . . 319
DIP Switch S1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Displacement Power Factor. . . . . . . . . . . . . . . . . . . . 323
dnE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
, 227
Down 2 Command . . . . . . . . . . . . . . . . . . . . . . . . . . . 372
Down Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370
Drive Baseblock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
Drive Capacity . . . . . . . . . . . .421
, 422, 423, 424, 425
Drive Capacity Selection . . . .421
, 422, 423, 424, 425
Drive Capacity Setting Fault . . . . . . . . . . . . . . . . . . . 236
Drive Capacity Signal Fault. . . . . . . . . . . . . . . 197
, 206
Drive Conformities . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Drive Cooling Fans . . . . . . . . . . . . . . . . . . . . . . . . . . 278
Drive Disabled . . . . . . . . . . . . . . . . . . . . . . . . . 199
, 227
Drive Does Not Allow Selection of Rotational
Auto-Tuning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
Drive Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323
Drive Enable. . . . . . . . . . . . . . . . . . . . . . . . . . . 372
, 375
Drive Enable Run Permissive. . . . . . . . . . . . . . . . . . .319
Drive Function Customization . . . . . . . . . . . . . . . . . .319
Drive Input Voltage Setting . . . . . . . . . . . . . . . . . . . .129
Drive Intended Use. . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Drive kVA Setting Error . . . . . . . . . . . . . . . . . . . . . . .200
Drive Mode. . . . . . . . . . . . . . 108
, 109, 110, 111, 376
Drive Mode Unit Monitor Selection. . . . . . . . . . . . . .400
Drive Models and Types. . . . . . . . . . . . . . . . . . . . . . . .42
Drive Motor Overload Protection. . . . . . . . . . . . . . . .446
Drive Node Address . . . . . . . . . . . . . . . . . . . . . . . . . .379
Drive Operation Status at Previous Fault . . . . . 152
, 413
Drive Overheat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199
Drive Overheat Alarm (OH2). . . . . . . . . . . . . . . . . . .370
Drive Overheat Warning. . . . . . . . . . . . . . . . . . . . . . .231
Drive Overload . . . . . . . . . . . . . . . . . . . . 198
, 216, 322
Drive Ready . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .374
Drive Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . .282
Drive Short-Circuit Rating . . . . . . . . . . . . . . . . . . . . .445
Drive Specifications . . . . . . . . . . . . . . . . . . . . . . . . . .317
Drive Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Drive Status . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
, 410
Drive Status Monitors. . . . . . . . . . . . . . . . . . . . . . . . .150
Drive Transmit Wait Time . . . . . . . . . . . . . . . . . . . . .380
Drive Watts Loss Data . . . . . . . . . . . . . . . . . . . . . . . .325
Drive/kVA Selection. . . . . . . . . . . . . . . . . . . . . . . . . .402
During Baseblock . . . . . . . . . . . . . . . . . . . . . . . . . . . .374
During Fast-stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . .376
During Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .374
During Run 2, Motor Switch Command Input. . . . . .200
During Torque Limit. . . . . . . . . . . . . . . . . . . . . . . . . .375
Duty Cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .348
Dwell Frequency at Stop . . . . . . . . . . . . . . . . . . . . . .343
Dwell Function . . . . . . . . . . . . . . . . . . . . . . . . . 191
, 318
Dwell Reference at Start. . . . . . . . . . . . . . . . . . . . . . .343
Dwell Time at Start. . . . . . . . . . . . . . . . . . . . . . . . . . .343
Dwell Time at Stop. . . . . . . . . . . . . . . . . . . . . . . . . . .343
Dynamic Braking Resistor . . . . . . . . . . . . . . . . . . . . .198
Dynamic Braking Transistor . . . . . . . . . . . . . . 198
, 220
E
E1 V/f Pattern Characteristics . . . . . . . . . . . . . . . . . .355
E-10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250
E1-01 . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
, 130, 355
E1-03 . . . . . . . . . 143
, 145, 250, 253, 255, 356, 420
E1-03 V/F Pattern Settings. . . . . . . . . . . . . . . . . . . . .420
E1-03 V/F Pattern Settings for Drive Capacity
200/400 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .420
E1-04 144
, 145, 239, 253, 255, 259, 261, 357, 420

Table of Contents

Other manuals for YASKAWA V1000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA V1000 Series and is the answer not in the manual?

YASKAWA V1000 Series Specifications

General IconGeneral
ModelV1000 Series
SeriesV1000
Output Frequency0.1 to 400 Hz
Overload Capacity150% for 60 seconds
TypeAC Drive
Control MethodV/f Control
Input Voltage200-240V, 380-480V
Output Voltage0 to Input Voltage
Power Range0.1 to 18.5 kW
Horsepower0.2 to 25 HP
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit, Ground Fault
Communication InterfacesModbus RTU
EnclosureIP20
Ambient Temperature-10 to +50°C
Storage Temperature-20 to +60°C
Humidity5 to 95% RH (non-condensing)
Cooling MethodFan Cooled