Send comments to nexus3k-docfeedback@cisco.com
-SM-182
Cisco Nexus 3000 Series NX-OS System Management Command Reference
OL-29557-04
Chapter System Management Commands
sflow counter-poll-interval
sflow counter-poll-interval
To configure an interval between sample counters associated with the datagram, use the sflow
collector-poll-interval command. To remove the interval, use the no form of this command.
sflow counter-poll-interval poll-interval
no sflow counter-poll-interval poll-interval
Syntax Description
Defaults None
Command Modes Global configuration
Command History
Usage Guidelines A sampling interval of 0 disables counter sampling.
This command does not require a license.
Examples This example shows how to configure the sFlow poll interval for an interface.
switch# configure terminal
switch(config)# sflow counter-poll-interval 100
switch(config)# copy running-config startup-config
Related Commands
poll-interval Poll interval for an interface. The range for the poll-interval is from 0 to
2147483647 seconds. The default value is 20.
Release Modification
5.0(3)U4(1) This command was introduced.
Command Description
feature sflow Enables sFlow.
show sflow Displays sFlow information.