EasyManua.ls Logo

Cisco Nexus 3000 series - Sflow Counter-Poll-Interval

Cisco Nexus 3000 series
356 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Send comments to nexus3k-docfeedback@cisco.com
-SM-182
Cisco Nexus 3000 Series NX-OS System Management Command Reference
OL-29557-04
Chapter System Management Commands
sflow counter-poll-interval
sflow counter-poll-interval
To configure an interval between sample counters associated with the datagram, use the sflow
collector-poll-interval command. To remove the interval, use the no form of this command.
sflow counter-poll-interval poll-interval
no sflow counter-poll-interval poll-interval
Syntax Description
Defaults None
Command Modes Global configuration
Command History
Usage Guidelines A sampling interval of 0 disables counter sampling.
This command does not require a license.
Examples This example shows how to configure the sFlow poll interval for an interface.
switch# configure terminal
switch(config)# sflow counter-poll-interval 100
switch(config)# copy running-config startup-config
Related Commands
poll-interval Poll interval for an interface. The range for the poll-interval is from 0 to
2147483647 seconds. The default value is 20.
Release Modification
5.0(3)U4(1) This command was introduced.
Command Description
feature sflow Enables sFlow.
show sflow Displays sFlow information.