DGS-3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide
1128
BPDU under attacking state
(mode: drop / block / shutdown)
BPDU attack
automatically recover
Port <[UnitID:]portNum> recover
from BPDU under attacking state
automatically
Informational
BPDU attack manually
recover
Port <[UnitID:]portNum> recover
from BPDU under attacking state
manually
Informational
MONITOR
Temperature exceeds
confidence level
[Uint <unitID>] Temperature
Sensor <sensorID> enter alarm
state. (current temperature:
<temperature>)
Warning
Temperature recovers to
normal.
[Uint <unitID>] Temperature
Sensor <sensorID> recovers to
normal state. (current
temperature: <temperature>)
Informational
CFM
Cross-connect is detected
CFM cross-connect.
VLAN:<vlanid>, Local(MD
Level:<mdlevel>, Port
<[unitID:]portNum>,
Direction:<mepdirection>)
Remote(MEPID:<mepid>,
MAC:<macaddr>)
Critical
Error CFM CCM packet is
detected
CFM error ccm. MD
Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>,
Direction:<mepdirection>)
Remote(MEPID:<mepid>,
MAC:<macaddr>)
Warning
Can not receive remote
MEP's CCM packet
CFM remote down. MD
Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>,
Direction:<mepdirection>)
Warning
Remote MEP's MAC
reports an error status
CFM remote MAC error. MD
Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>,
Direction:<mepdirection>)
Warning
Remote MEP detects
CFM defects
CFM remote detects a defect.
MD Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>,
Direction:<mepdirection>)
Informational
CFM EXTENSION
AIS condition detected
AIS condition detected. MD
Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>,
Direction:<mepdirection>,
MEPID:<mepid>)
Notice
AIS condition cleared
AIS condition cleared. MD
Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>,
Direction:<mepdirection>,
MEPID:<mepid>)
Notice
LCK condition detected
LCK condition detected. MD
Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>,
Direction:<mepdirection>,
MEPID:<mepid>)
Notice
LCK condition cleared
LCK condition cleared. MD
Level:<mdlevel>,
VLAN:<vlanid>, Local(Port
<[unitID:]portNum>,
Direction:<mepdirection>,
MEPID:<mepid>)
Notice
Voice VLAN
When a new voice device
is detected in the port
New voice device detected
(MAC:<macaddr>,Port:<[unitID:]
Informational

Table of Contents