xStack
®
DGS-3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide
361
high_alarm - (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<voltage> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<voltage> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<voltage> - Enter the high threshold warning value here.
low_warning - (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<voltage> - Enter the low threshold warning value here.
bias_current_threshold - Specify the threshold of the optic module’s bias current.
high_alarm - (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<milliampere> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<milliampere> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<milliampere> - Enter the high threshold warning value here.
low_warning - (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<milliampere> - Enter the low threshold warning value here.
tx_power_threshold - Specify the threshold of the optic module’s output power.
high_alarm - (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the high threshold warning value here.
low_warning - (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the low threshold warning value here.
rx_power_threshold - Specify the threshold of optic module’s received power.
high_alarm - (Optional) Specify the high threshold for the alarm. When the operating
parameter rises above this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the high threshold alarm value used here.
low_alarm - (Optional) Specify the low threshold for the alarm. When the operating parameter
falls below this value, the action associated with the alarm is taken.
<mw_or_dbm> - Enter the low threshold alarm value used here.
high_warning - (Optional) Specify the high threshold for the warning. When the operating
parameter rises above this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the high threshold warning value here.
low_warning - (Optional) Specify the low threshold for the warning. When the operating
parameter falls below this value, the action associated with the warning is taken.
<mw_or_dbm> - Enter the low threshold warning value here.
state - (Optional) Specify the DDM state to enable or disable. If the state is disabled, no DDM
action will take effect.
enable - Specify to enable the DDM state.
disable - Specify to disable the DDM state.
shutdown - (Optional) Specify whether or not to shutdown the port when the operating
parameter exceeds the corresponding alarm threshold or warning threshold.
alarm - Shutdown the port when the configured alarm threshold range is exceeded.
warning - Shutdown the port when the configured warning threshold range is exceeded.
none - The port will never shutdown regardless if the threshold ranges are exceeded or not.

Table of Contents

Other manuals for D-Link xStack DGS-3120 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link xStack DGS-3120 Series and is the answer not in the manual?

D-Link xStack DGS-3120 Series Specifications

General IconGeneral
MAC Address Table16K entries
Ports10/100/1000BASE-T ports
VLANs4094
Jumbo FrameUp to 9KB
Power SupplyInternal power supply (depending on model)
Power over Ethernet (PoE)No
Layer 3 FeaturesRIP
Quality of Service (QoS)8 queues per port, DiffServ
Security FeaturesACLs
ManagementWeb-based, CLI, SNMP
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
SFP PortsCombo 10/100/1000BASE-T/SFP ports and/or dedicated SFP/SFP+ ports (depending on model)