947
Format
config sflow analyzer_server <value 1-4> {timeout [<sec 1-2000000> | infinite] |
collectoraddress <ipaddr> | collectorport <udp_port_number 1-65535> | maxdatagramsize
<value 300-1400>}
Parameters
analyzer_server - The ID of analyzer server.
<value 1-4> - Enter the analyzer server ID here. This value must be between 1 and 4.
timeout - (Optional) The time (in seconds) remaining before the sample is released and stops
sampling. When the analyzer_server times out, all of the flow_samplers and counter_pollers
associated with this analyzer_server will be deleted.
<sec 1-2000000> - Enter the time-out value here. This value must be between 1 and 2000000
seconds.
infinity - Indicates the analyzer server never timeout
collectoraddress - (Optional) The IP address of the server. If not specified or set a 0 address,
sFlow packets will not be sent to this server.
<ipaddr> - Enter the IP address used for the configuration here.
collectorport - (Optional) The destination UDP port for sending the sFlow datagram. If not
specified, the default value is 6364
<udp_port_number 1-65535> - Enter the destination port number here. This value must be
between 1 and 65535.
maxdatagramsize - (Optional) The maximum number of data bytes that can be packed in a
single sample datagram. If not specified, the default value is 1400 bytes.
<value 300-1400> - Enter the maximum datagram size here. This value must be between 300
and 1400.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
Configure the host 10.90.90.90 to be the sFlow analyzer server with the ID 1:
DGS-3120-24TC:admin# config sflow analyzer_server 1 collectoraddress
10.90.90.90
Command: config sflow analyzer_server 1 collectoraddress 10.90.90.90
Success.
DGS-3120-24TC:admin#
98-9 delete sflow_analyzer_server
Description
This command is used to delete a specified analyzer server.
Format
delete sflow analyzer_server <value 1-4>

Table of Contents

Other manuals for D-Link xStack DGS-3120 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link xStack DGS-3120 Series and is the answer not in the manual?

D-Link xStack DGS-3120 Series Specifications

General IconGeneral
MAC Address Table16K entries
Ports10/100/1000BASE-T ports
VLANs4094
Jumbo FrameUp to 9KB
Power SupplyInternal power supply (depending on model)
Power over Ethernet (PoE)No
Layer 3 FeaturesRIP
Quality of Service (QoS)8 queues per port, DiffServ
Security FeaturesACLs
ManagementWeb-based, CLI, SNMP
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
SFP PortsCombo 10/100/1000BASE-T/SFP ports and/or dedicated SFP/SFP+ ports (depending on model)

Related product manuals