Operation of the Hydraulic Zero Setting of Blades (Optional)
207
Pos: 53.11 /BA/Inf o-Center/Rundballenpr esse/Hand-/Auto matikbetrieb/Alar mmeldungen bei Messernu llschaltung CCI @ 214\ mod_1390474160730_78. docx @ 1756784 @ 22 @ 1
10.1.1.2 Alarm messages for blade comfort selection
Notes and messages
No. Figure Possible cause Remedy
14
Blade base is not closed.
Close blade base using tractor
hydraulics.
Check the setting of the "Blade
base monitoring" sensor.
32
Blade preselection has been
changed
Engage (activate) blade using
tractor hydraulics
33
Blade preselection has been
changed.
Disengage (deactivate) blade
using tractor hydraulics.
34
Blade selection A sensors set
incorrectly.
"Blade A on" and "Blade A
off" sensors have same
signal.
Check the setting of the blade
selection A sensors.
35
Blade selection B sensors set
incorrectly.
"Blade B on" and "Blade B
off" sensors have same
signal.
Check the setting of the blade
selection B sensors.
Physical messages
No. Symbol Sensor Possible cause Remedy
108
Blade base position
140
Blade B off
141
Blade B on
Sensor or line
defective.
– Perform sensor
test.
Check sensor and
line for damage.
142
Blade A off
143
Blade A on