Malfunctions - Causes and Remedies
345
Pos: 63.8 /Überschri ften/Überschri ften 2/P-T/Störungen an der zentralen Kettensc hmierung @ 35\mod_1256199 185431_78.docx @ 3270 48 @ 22 @ 1
16.2 Malfunctions on the central chain lubrication system
Pos: 63.9 /BA/Störungen - Ursachen und Behebung/ Rundballenpressen/ Tabellarische Auf listung Kettenschmier ung @ 240\mod_1395153 485543_78.docx @ 1891808 @ @ 1
Malfunction Possible cause Remedy
Low oil consumption
Low pressure
Pump works with difficulty, dirt in the
pump area
• Clean
Pump is not pressed to a full stroke
Adjust according to the operating
instructions
Pump valve does not close correctly
Remove and clean or replace
Oil is too thick Replace with recommended oil
System contaminated
Clean or replace all measuring
valves
Oil consumption too high Main pipe torn Repair or replace
Oil too thin Drive with thicker oil
Reduce the pump stroke
Machine is dry No pressure
Pump not running
Repair, adjust or replace
Main pipe torn
Repair or replace
System has no oil
Vent the system (see chapter
Central chain lubrication system)
System blocked Dirt
Clean the system and clean or
replace all measuring valves.
Pipe jammed
Repair or replace
Pump is not pressed to a full
stroke.
Oil is too thick, nozzles clogged.
Replace with recommended oil
• Clean nozzles