Processing
The mail transmission settings of [S1] to [S4] are stored in the mail transmission setting area.
The instruction can be executed when the mail send request relay is OFF (0: No request). As
an execution condition of the instruction, insert a program that checks the state of the mail
send request relay. The state of the mail send request relay can be read with the ETSTAT
instruction. Store the state that is read in a device such as an internal relay. An operation
error occurs if this instruction is executed when the send request relay is ON.
This instruction can be executed when the Ethernet initialization active flag (X61) is OFF. As
an execution condition of the instruction, insert a program that checks the status of the flag
(X61). If this instruction is executed when the flag (X61) is ON, the system relay SR9 (carry
flag CY) is set and the instruction is terminated without being executed.
When the instruction is completed successfully, the system relay SR9 (carry flag CY) and the
system data register SD29 (Ethernet communication error code) are cleared.
Precautions for programming
Insert the UNITSEL instruction immediately before this instruction and specify the unit (built-
in ET-LAN in the CPU unit) and the connection number.
For [S1] to [S4], specify the starting address of the device area that stores the string data
that indicates the set parameters, or a character constant. When specifying a device area for
an operand, set string data using the SSET instruction in advance. However, the ESSET
instruction cannot be used because the format is different.
Both upper and lower case characters can be used. "Abcd", "ABCD" and "abcd" are all
synonymous. However, the subject, the mail text, and the attachment file name are case-
sensitive.
This instruction is not available in interrupt programs.
Operand [S1] setting
Specify the starting address of the device area that stores the string data that indicates a
setting number (string) and a send trigger, or a character constant.
Setting item Settings
Setting
range
S1
Setting
number
Specify a transfer setting number. Specify the keyword “ID=” at
the beginning.
ID=: Transfer setting number
0 to 15
Send trigger
Specify a send trigger. Specify the keyword “TRIG=” at the beginning.
TRIG=xxxxx
* For information on send triggers, refer to "Operand [S1] send trigger setting".
(Note 1) Only one setting number and send trigger can be specified simultaneously.
(Note 2) It is prohibited to specify the same keyword redundantly. An error is caused in the case of redundant
specification.
(Note 3) Input each setting parameter separated by a comma ",".
(Note 4) Each parameter cannot be omitted. Specify them in the order of the above table. The order of
keywords cannot be changed.
(Note 5) Upper and lower case characters can be used for specifying keywords.
(Note 6) Setting numbers should be specified from number 0 in ascending order. An error occurs when transfer
setting numbers are not specified in ascending order. If transfer settings have been already registered,
this rule is not applied.
17.24 SMTPcSET (Mail Transmission Setting)
WUME-FP7CPUPGR-12 17-121

Table of Contents

Other manuals for Panasonic FP7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FP7 Series and is the answer not in the manual?

Panasonic FP7 Series Specifications

General IconGeneral
BrandPanasonic
ModelFP7 Series
CategoryController
LanguageEnglish

Related product manuals