Shift input
Instruction
operation
RUN
(Power on)
Shifted
Not shifted
Be careful when using this instruction with an instruction that changes the order of instruction
execution such as MC - MCE or JP - LBL (1 to 6, shown below), because the operation of
the instruction may change depending on the timing of the instruction execution and shift
input.
1) MC - MCE instructions
2) JP - LBL instructions
3) LOOP - LBL instructions
4) CNDE instruction
5) Step ladder instructions
6) Subroutine instructions
When using an LRSR instruction with an AND stack (ANS) instruction or pop stack (POPS)
instruction, be sure to write the code correctly.
Flag operations
Name Description
SR7, SR8 (ER) Turns ON when [D1] address > [D2] address.
SR9(CY) Turns ON when the value pushed out due to shifting is "1."
3.24 LRSR (Left/Right Shift Register)
WUME-FP7CPUPGR-12 3-75