Acquired data (W2 link error system counter type error area): When [S] = 2
Storag
e
locatio
n
Items Range: Description
[D] Number of lost tokens
U0 to U255
The number of occurrences of each error
is stored.
[D+1] Number of duplicate tokens
[D+2]
Number of occurrences of non-signal
state
[D+3]
Number of occurrences of synchronous
abnormality
[D+4]
Number of occurrences of send NACK
error (When an error occurs)
[D+5]
Number of occurrences of send NACK
error (At the time of third retry)
[D+6]
Number of occurrences of send WACK
error (When an error occurs)
[D+7]
Number of occurrences of send WACK
error (When occurred 16 times
continuously)
[D+8]
Number of occurrences of non-
response (When an error occurs)
[D+9]
Number of occurrences of non-
response (At the time of third retry)
[D+10]
Number of receptions of undefined
commands
[D+11]
Number of occurrences of receive
parity check error
[D+12]
Number of occurrences of END CODE
reception error
[D+13]
Number of occurrences of received
data format error
[D+14]
Number of occurrences of received
data NOT support error
[D+15] Number of token retransmissions
[D+16] Number of detection of unit OFF
[D+17]
Number of occurrences of link error
state
16.4 PMGET (Acquiring MEWNET-W2 Parameters)
16-16 WUME-FP7CPUPGR-12