Setting
item
Settings
Setting
range
Parameter Extension (Saving
format)
BIN1w Unconverted 16-bit binary .BIN (binary data)
US 16-bit unsigned decimal
.CSV
(comma-separated text)
SS 16-bit signed decimal
UL 32-bit unsigned decimal
SL 32-bit signed decimal
SF
32-bit single-precision floating
point
DF
64-bit double-precision floating
point
HEX1w 16bitHEX
HEX2w 32bitHEX
HEX4w 64bitHEX
ASCII
ASCII character (Output
enclosed with "")
Line feed
position
Specify line feed position.
0: Output the end of file only
n: Output by n data
0 to 255
(Note 1) Input each source device setting parameter separated by a comma ",".
(Note 2) Specify the operation setting parameters in the order of the above table.
(Note 3) When omitting "conversion method" and subsequent items, the conversion method is set to 16-bit
binary and the line feed position is set to 0 (output the end of file only).
(Note 4) When omitting "Line feed position", it is set to 0: Output the end of file only.
Setting example
Exam
ple 1
S3 "WX16,32,BIN1w,0"
Settings
Device setting, Device division: Global, Device code: WX, Device No.: 16
Number of transferred data: 32 (32 words), Conversion method: Unconverted 16-bit binary, Line
feed position: Output the end of file only
Exam
ple 2
S3 "DT123456,250,SS,10"
Settings
Device setting, Device division: Global, Device code: DT, Device No.: 123456
No. of transferred data: 250 points (250 words), Conversion method: 16-bit signed decimal, Line
feed position: Output by 10 data
Exam
ple 3
S3 "WR0,16,DF"
Settings
Device setting, Device division: Global, Device code: WR, Device No.: 0
No. of transferred data: 16 points (64 words), Conversion method: 64-bit double-precision floating
point, Line feed position: Output the end of file only
Exam
ple 4
S3 "WL10,128"
17.12 FTPcSET (FTP Client Transfer Setting)
17-64 WUME-FP7CPUPGR-12