62C-36
AFTER REPAIR Carry out a full check with the diagnostic tool.
V1
MR-453-X79-62C000$080.mif
62C
ALP 2 Air distribution fault
NOTES
Make sure that the air circuit (cabin filter, scuttle panel grille, air ducts etc.) is not
blocked.
Check that the air circuit (cabin filter, scuttle panel grille, air vents and extractors etc.) is not blocked.
Ensure that the passenger compartment fan blades are in good condition.
Repair, clean or change the cabin filter if necessary.
Ensure that the blower unit is properly sealed.
Repair if necessary.
Set the passenger compartment blower to
maximum speed with maximum hot or maximum
cold and move the air distribution control.
Check that the air outlet is the one selected.
Is the air distribution correct?
The air distribution is operating
correctly.
Explain to the customer how the
system operates.
YES
NO
A
CLIMATE CONTROL
Fault finding – Fault finding chart