62C-37
AFTER REPAIR Carry out a full check with the diagnostic tool.
V1
MR-453-X79-62C000$080.mif
CLIMATE CONTROL
Fault finding – Fault finding chart
62C
ALP 2
CONTINUED 1
Remove the glovebox and the centre console in
order to visually check whether moving the
control causes the distribution flaps to move.
Does it move?
Check that the distribution flaps
are in good condition, the footwell
distribution flap linkages are in
position, and that there is no
mechanical obstruction. If
necessary, repair or replace the
air conditioning unit.
A
NO
YES
B
NO