280
442703/B
eWritedowntheinformation.
fClosetheCommandPromptwindow.
SelecttheadapterthattheOperatingPanelisconnectedto.OntheST90,the
EthernetadapterisnamedSimradConnect.
PreparetheOperatingPanelforuse.
2Makethefollowingpreparations.
aConnectthepowercablefromtheOperatingPaneltothepoweroutletonthe
uninterruptiblepowersupply(UPS).
bConnecttheEthernetcablefromtheProcessorUnittotheOperatingPanel.
MakesurethatyouusethecorrectEthernetsocketontherearsideofthe
ProcessorUnit:ETH1
cConnectthekeyboardandthemousetoUSBsocketsonthefrontpanelof
theProcessorUnit.
dOntheProcessorUnit,closeanyprogramsthatarerunning,andreturnto
thedesktop.
eOntheOperatingPanel,pressPower,andkeepitdepressedforafewseconds.
TheblueindicatorlightinthebuttonasheswhiletheOperatingPanel
establishescontactwiththeProcessorUnit.Whenyoustartthepanelforthe
rsttimetheinterfacemustbeconguredtoestablishthisconnection.When
theconnectionhasbeenmade,theblueindicatorlightislitpermanently.
fOntheProcessorUnitdesktop,openfolderSIMRAD-Shortcut.
gDouble-clickleIPandMACaddress.txttoopenitinatexteditor.
hDouble-clicktheURLshortcuttoopentheOperatingPanelcongurationpage
inthedefaultwebbrowser.
ObservethattheOperatingPanelcongurationpageopenson
page157.237.60.20:5000
3Denethecongurationparameters.
aSelectSOPCongurationonthetopmenutoopenthepage.
bObservethedefaultvalues.
Ifyouwishtokeepthesedefaultvalues,donothing.Thedefaultvaluesare
wellsuitedifyouhaveonesinglepanelcommunicatingwithonesingle
ProcessorUnit.Forothercongurations,seetherelevantprocedures.
4AddasingleProcessorUnittotheOperatingPanelconguration.
aSelectSonarPCsCongurationonthetopmenutoopenthepage.
bTypeorcopytheIPaddressintotherelevantbox.
cTypeorcopytheMACaddressintotherelevantbox.
dSelectADDSonarPC.
SimradST90InstallationManual