290
442703/B
Certainstepsinthetwoproceduresarelocationspecic.Thestepsmarked[Sonarroom]
aredoneinthesonarroom.Thestepsmarked[Bridge]aredoneonthebridge.
Procedure
1MakesurethatallEthernetcablesareconnected.
2Makesurethatthetransceiverplughasbeenconnectedtothededicatedsocket
ontheleftsideoftheTransceiverUnit.
3UseaspannertoopenthedoorontheMotorControlUnit.
4LocateHoist/LowerSwitch(S302).
5SettheswitchtopositionREMOTE.
Relatedtopics
Settingtoworksummary,page242
TurningontheST90forthersttime,page276
Turningontheentiresystem-Bridgesteps
Whenallcableshavebeenproperlyconnected,theST90canbestarted.Inorderto
turnontheST90forthersttimeinacontrolledmanner,twotasksmustbedone
simultaneously.Thesetasksaredoneonthebridge.
Prerequisites
TheST90isinstalledasspeciedinthismanual.
•ThedoorontheTransceiverUnitisremoved.
•ThedoorontheMotorControlUnitisopen.
Youmustbeequippedwithastandardsetoftools.Thistoolsetmustcomprisethe
normaltoolsforelectronicandelectromechanicaltasks.
Context
Certainstepsinthetwoproceduresarelocationspecic.Thestepsmarked[Sonar
room]aredoneinthesonarroom.
Procedure
1Makesurethatyouhavesufcientwaterdepthbelowthekeelbeforeyoulower
thetransducer.
2TurnontheST90.
aTurnonthedisplay.
bTurnontheProcessorUnit.
SimradST90InstallationManual