Best Practices
l Never clean bulkhead connectors or receptacle devices without a
means to inspect them.
l Never touch the end face of the fiber connectors.
l Never twist or pull forcefully on the fiber cable.
l Never reuse any tissue, swab, or cleaning cassette reel.
l Never touch the clean area of a tissue, swab, or cleaning fabric.
l Never touch any portion of a tissue or swab where alcohol was
applied.
l To prevent contamination, never touch the dispensing tip of an
alcohol bottle.
l Never use alcohol for wet cleaning without a way to ensure that it
does not leave residue on the end face. Alcohol residue can
damage the equipment (for advanced user only).
391 FSP 3000R7 High-Density Subshelf Guide - R17.2 - Issue:B