108 Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Chapter 5 Use the Keypad Interface
Digital Input Diagnosis Operation
When external output signal triggers DI1…DI10, the display shows the
corresponding signal by bit. When the bit is equal to 1, the DI is on.
For example, if hexadecimal number 3FE1 is displayed, the binary equivalent for
E is 1110, then DI6…DI8 are on.
Digital Output Diagnosis Operation
The output signal DO1…DO5 are triggered and the corresponding signals are
shown on the display by bit. When 1 is displayed, the DO is on.
For example, if hexadecimal number 1F, is displayed, the binary equivalent for F
is 1111, then DO1…DO4 are on.
Display Firmware Upgrade Information
See Upgrade the Drive Firmware on page 453.
S
1 1 1 1 1 1 1 1 1 0 0 0 0 1
14 13 12 11 10 9 8 7 6 5 4 3 2 1
Binary code
Corresponding DI status
The display is in hexadecimal format.
S
0 0 0 1 1 1 1 1
5 4321
Binary code
Corresponding DI status
The display is in hexadecimal format.