Rockwell Automation Publication 2198-UM004A-EN-P - October 2019 109
Chapter 6
Set Up EtherNet/IP Communication
You can include the drive in your Studio 5000 Logix Designer® application by
adding it to a configured EtherNet/IP™ module or controller under the I/O
configuration tree. After setting network parameters, you can view the drive
status information in Studio 5000® environment and use it in your Logix
Designer application.
Settings are stored in nonvolatile memory. IP addressing can also be changed
through the Module Configuration dialog box in RSLinx® software or through
the Internet Protocol page of Module Properties in your Logix Designer
application. Changes to the IP addressing take effect after power is cycled.
If configure DHCP is turned ON in the Network Parameters, you must
configure the IP address of drive by using BOOTP/DHCP tool.
Use one of the following three methods to set the network parameters:
Panel display
KNX5100C software on page 111
BOOTP/DHCP tool on page 112
The drive is factory programmed to static IP address of 192.168.1.1 and Gateway
address of 192.168.1.254.
Set Network Parameters by
Using the Display
1. Apply power to your drive.
BOOTx appears on the display as the drive boots up. After a successful
boot process, the drive display scrolls 5100 192.168.1.1, then STOP
192.168.1.1.
Topic Page
Set Network Parameters by Using the Display 109
Set Network Parameters by Using the KNX5100C Software 111
Configure IP Address by Using BOOTP/DHCP Tool 112