Rockwell Automation Publication 2198-UM004A-EN-P - October 2019 55
Connector Data and Feature Descriptions Chapter 3
Analog Outputs
There are two analog outputs, AOUT1 and AOUT2, available on the I/O
connector.
Table 31 - Analog Output Specifications
Figure 32 - Analog Output Configuration
Parameter Description
Analog outputs voltage –8V… +8V DC or -10V…+10VDC, user configurable
Analog outputs resolution 10 bits, min
Analog outputs current 1 mA, max
Analog outputs scan time 0.25 ms, max
AGND
24 kΩ
Output:
1 mA, max
8 kΩ
8V
Full-scale
V
13
16
15
AOUT1
AOUT2
Analog GND
Servo Drive