186 Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Chapter 9 Tuning
Figure 77 - Settings for SysGainResponseLevel
Command
Response
Feedback
Position
Time
Before
Command
Response
Feedback
Position
Time
After
Servo
Bandwidth
Level Increases
84 Hz
26 Hz
ID216 (P2.031) = 30
ID216 (P2.031) = 20
5 Inertia Ratio
ID144 (P1.037)