426 Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Chapter 16 Troubleshoot the Kinetix 5100 Drive System
Table 130 - MOD LED Status Indicators
Operation Mode LED Color Status Description
I/O Steady off No power If no power is supplied to the device, the module status
indicator shall be steady off.
Steady green Device operational If the device is operating correctly (IO connection is established
successfully), the module status indicator shall be steady green.
Flashing green Standby If the device has not been configured, the module status
indicator shall be flashing green.
Flashing red Major recoverable fault or
Minor recoverable fault
If the device has detected a major or minor recoverable fault,
the module status indicator shall be flashing red.
NOTE: An incorrect or inconsistent configuration could be
considered a major recoverable fault.
Steady red Major unrecoverable fault If the device has detected a major unrecoverable fault, the
module status indicator shall be steady red.
Flashing green/red Self-test While the device is performing its power up testing, the module
status indicator shall be flashing green/red.
Standalone Steady off No power If no power is supplied to the device, the module status
indicator shall be steady off.
Steady green Device operational If the device is operating correctly (after the drive boots
successfully), the module status indicator shall be steady green.
Flashing red Major recoverable fault or
Minor recoverable fault
If the device has detected a major or minor recoverable fault,
the module status indicator shall be flashing red.
NOTE: An incorrect or inconsistent configuration could be
considered a major recoverable fault.
Steady red Major unrecoverable fault If the device has detected a major unrecoverable fault, the
module status indicator shall be steady red.
Flashing green/red Self-test While the device is performing its power up testing, the module
status indicator shall be flashing green/red.
Table 131 - NET LED Status Indicators
LED Color Status Description
Steady off No power or no IP address The device is powered off, or is powered on but with no IP
address configured.
Steady green Connected An IP address is configured, at least one CIP™ connection (any
transport class) is established, and an Exclusive Owner
connection has not timed out.
Flashing green Not connected An IP address is configured but no CIP connections are
established, and an Exclusive Owner connection has not timed
out.
Flashing red Connection timeout An IP address is configured, and an Exclusive Owner connection
where this device is the target has timed out.
Steady red A duplicate IP address has
been identified
The device has detected that (at least one of) its IP address is
already in use.
Flashing green/red Self-test While the device performs its power up testing.
Table 132 - CHARGE LED Status Indicators
LED Color Status Description
Steady off No power When no power is supplied to the device.
Steady orange DC bus voltage operational When the DC bus voltage is above 50V DC.