EasyManua.ls Logo

Allen-Bradley Kinetix 5100 2198-E1004-ERS - Safe Torque Off Connector Data

Allen-Bradley Kinetix 5100 2198-E1004-ERS
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
382 Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Chapter 13 Kinetix 5100 Safe Torque Off (STO) Feature
Safe Torque Off Connector
Data
The Kinetix 5100 drive ships with the (8-pin) wiring-plug header that connects
your safety circuit to the Kinetix 5100 drive Safe Torque Off (STO) connector.
The header includes jumper wires that by-pass the safety function for drives that
do not use the Safe Torque Off feature. Remove the jumper wires when the Safe
To r qu e Of f f eatur e i s us e d .
Figure 195 - Pin Orientation for 8-pin Safe Torque-off Connector
Table 113 - Kinetix 5100 Drive Safe Torque Off Connector Pinout
SB–
S1C
S2C
SS–
SB+
S1
S2
SS+
Description Signal
Used for safety jumper + SB+
Used for safety jumper – SB–
STO_A+ S1
STO_A– S1C
STO_B+ S2
STO_B– S2C
Safety status or feedback SS+
Safety status or feedback SS–
IMPORTANT Use pins SB+ and SB– only for the by-pass jumpers to defeat the Safe Torque
Off function. When the Safe Torque-off function is in operation, the 24V supply
must come from an external source.