156 Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Chapter 7 Configure the Drive with KNX5100C Software
Click Download to download any changed parameters to the servo drive.
Configure Velocity Loop
Choose Velocity Loop from the Function List to change the parameters that
apply to velocity command.
Table 63 - Relevant Parameters
Parameter Name
ID189 (P2.004) VelocityProportionalGain
ID191 (P2.006) VelocityIntegralGain
ID192 (P2.007) AccelerationFeedforwardGain
ID232 (P2.049) VelocityFeedforwardLowPassFilterTimeConstant
ID144 (P1.037) LoadInertiaRatio