490 Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Appendix E Use the Scope Function in KNX5100C Software
Scope Functions
To execute Scope functions, click icons on the toolbar.
Save File (*.scp): Save the waveform displays on the screen as a scope file
(*.scp) or other files in several kinds of format.
Open File (*.scp): Open and read the scope file (*.scp) and display the
waveform displays on the screen.
Show all channels with same scaling: Display the channel data with the
different scaling/axis on the screen.
Show all channels with different scaling: Display the channel data with the
same scaling/axis on the screen.
Zoom in (F5). Zoom in to the waveform displays on the current screen.
Zoom out (F6). Zoom out of the waveform displays on the current screen.
Previous screen (F7). Display the previous screen.
Optimize the current view: Optimize the display in the current screen.
Clear Screen. Clear the waveform displays on the current screen.
Screen second switch (20 <-> 120). It is used to select the data buffer (X-
axis) that the screen can display one time. When selecting 20, it indicates
that the screen can display 20 seconds of data buffer for one time.
Run: start to execute the Scope.
Quick tool: select the Quick Setup from the Quick tool template.
Add: add the current channel setting to Quick tool template.
Update: update the current channel setting to Quick tool template.
Delete: delete the selected Quick Setup from Quick tool template.
Quick Setup of
Communication Channels
Use the pull-down menu to select monitor option from Quick tool template and
do the quick setup of Communication Channels.
E005 Analysis - Quick setup for E005 (Regeneration Error) Analysis.
E009 Analysis - Quick setup for E009 (Excessive deviation of Position
Command) Analysis.
E02C Analysis - Quick setup for E02C (Drive Overload) Analysis.
Tuning Gain Analysis - Quick setup for Gain Analysis.
Tuning Vibration Analysis - Quick setup for Vibration Analysis.
Pulse command analysis - Quick setup for Pulse command analysis.
Speed-torque Analysis - Quick setup for Speed-torque Analysis.