Rockwell Automation Publication 2198-UM004A-EN-P - October 2019 497
Use the Scope Function in KNX5100C Software Appendix E
When all Channel checkboxes are checked, the waveform displays of all
channels can be zoomed in/out and moved.
Zoom Time-axis only - If this option is not selected, the values of Time
axis do not change when you zoom in/out and move the waveform
displays.
Zoom Value-axis only - If this option is not selected, the values of Value
axis do not change when you zoom in/out and move the waveform
displays.
Align Time axis based on this CH - When this button is clicked, the
system changes the time of other channels and make it the same as the time
of the selected channel.
Specify Display Range - The start and end values are the start and end
points of the data. To convert these values into time, multiply by the time
unit. For example:
Time unit is 0.125 ms
Start point is 100, therefore, 100 * 0.125 = 12.5 ms
Endpoint is 2000, therefore 2000 * 0.125 = 250 ms
Set Preferences
Keep current Max/Min while running - The scope remains the current
Max/Min value after the user pressing RUN if this setting is checked. The
system uses the default Max/Min value if this option is not checked.
Show Grid Line - The scope screen shows the grid line when selecting this
option. The square button on left is to select the color of the grid line.
Auto adjust the scope display - The system adjusts the size of scope
automatically according to screen resolution and selected condition.
Show saving preference options - The options that appear when you right-
click on the screen.