158 Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Chapter 7 Configure the Drive with KNX5100C Software
Digital I/O and Jog Function
in KNX5100C Software
From the Function List, choose Digital IO/Jog Function to view or change the
configured function and status of digital inputs (DI) and digital outputs (DO),
or to activate signals manually.
There are three areas on the dialog box: Digital Input (DI), Digital Output
(DO), and Jog.
Configuration and Status of Digital Input (DI) and Digital Output (DO)
Signals
In the DI and DO areas, both signal types are shown with their individual
settings and contact type.
If the contact type of the DI or DO signal is normally closed, 'NC' is added at the
end of the signal name.
This dialog box also shows the On/Off status of the DI or DO signals.