24 Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Chapter 2 Plan and Install the Kinetix 5100 Drive System
Table 6 - Input Power UL/CSA Circuit-protection Specifications
Table 7 - Input Power IEC (non-UL/CSA) Circuit-protection Specifications
Kinetix 5100 Drive
Cat. No.
Drive Voltage
Fuses (Bussmann)
Cat. No.
Miniature CB
(1)
Cat. No.
Molded Case CB
Cat. No.
2198-E1004-ERS
120V/230V, single-phase KTK-R-15 (15 A) 1489-M2D100 –
230V, three-phase KTK-R-10 (10 A) 1489-M3D100 –
2198-E1007-ERS
120V/230V, single-phase KTK-R-20 (20 A) 1489-M2D200 –
230V, three-phase KTK-R-15 (15 A) 1489-M3D130 –
2198-E1015-ERS
120V/230V, single-phase KTK-R-30 (30 A) 1489-M2D300 –
230V, three-phase KTK-R-25 (25 A) 1489-M3D200 –
2198-E1020-ERS
120V/230V, single-phase LPJ-40SP (40 A) 1489-M2D400 –
230V, three-phase LPJ-35SP (35 A) 1489-M3D300 –
2198-E2030-ERS
230V, three-phase
LPJ-50SP (50 A) 1489-M3D350 –
2198-E2055-ERS LPJ-70SP (70 A) 1489-M3D600 –
2198-E2075-ERS LPJ-80SP (80 A) – 140G-G2C3-C70
2198-E2150-ERS LPJ-125SP (125 A) – 140G-G2C3-D12
(1) There are no recommended motor-protection circuit breakers for the Kinetix 5100 servo drives.
Kinetix 5100 Drive
Cat. No.
Drive Voltage
DIN gG Fuses
Amps, Max
Miniature CB
(1)
Cat. No.
Molded Case CB
Cat. No.
2198-E1004-ERS
120V/230V, single-phase 15 1489-M2D100 –
230V, three-phase 10 1489-M3D100 –
2198-E1007-ERS
120V/230V, single-phase 20 1489-M2D200 –
230V, three-phase 15 1489-M3D130 –
2198-E1015-ERS
120V/230V, single-phase 30 1489-M2D300 –
230V, three-phase 25 1489-M3D200 –
2198-E1020-ERS
120V/230V, single-phase 40 1489-M2D400 –
230V, three-phase 35 1489-M3D300 –
2198-E2030-ERS
230V, three-phase
50 1489-M3D350 –
2198-E2055-ERS 70 1489-M3D600 –
2198-E2075-ERS 80 – 140G-G2C3-C70
2198-E2150-ERS 125 – 140G-G2C3-D12
(1) There are no recommended motor protection circuit breakers for the Kinetix 5100 servo drives.