Rockwell Automation Publication 2198-UM004A-EN-P - October 2019 117
Configure the Drive with KNX5100C Software Chapter 7
4. From the Catalog field, select your Micro controller.
In this example, Micro850® (24QBB) is used.
5. Click Add To Project.
6. From the Controller Menu, click Ethernet to configure the Network
settings of the controller.
This step is required to control the Kinetix 5100 drive through message
instructions.
In this example, we used the IP address of 192.168.1.89.
7. From the Controller menu, expand Plug-in Modules or Expansion
Modules, then right-click <empty> to add analog output module (2080-
OF2 or 2085-OF4).