Rockwell Automation Publication 2198-UM004A-EN-P - October 2019 487
Full Closed Loop Control Appendix D
6. Configure Low-pass filter time constant ID174 (P1.075)
FullHalfClosedLoopLowPassFilterTime.
7. Configure the error reset function when switch between full closed-loop
control and half closed-loop control ID676 (P1.084)
FullClosedLoopPositionErrorResetConfiguration.
8. Configure the error auto-reset condition ID677 (P1.085)
FullClosedLoopPositionErrorAutoResetThreshold.
9. Configure encoder output parameters, if necessary ID119 (P1.003.Y),
ID173 (P1.074.Y), ID153 (P1.046), ID175 (P1.076), ID179 (P1.097)).
10. Start full closed-loop control function ID173 (P1.074.X)
FullClosedLoopControlConfiguration.