60 Rockwell Automation Publication 2198-UM004A-EN-P - October 2019
Chapter 3 Connector Data and Feature Descriptions
7. In Brake Time Settings, enter ID149 (P1.042) Disengage Delay Time and
ID150 (P1.043) Engage Delay Time parameter values.
8. Verify that the MotorStopMode ID675 (P1.032) parameter is set to 0000.
Refer to Parameter Editor screen General parameter group.
TIP For vertical loads, MotorStopMode 0000 controls the motor to below the ID145
(P1.038) motor speed where the brake function executes (see Figure 37
).