AMCC Proprietary 193
Revision 1.02 - September 10, 2007
PPC405 Processor
crand
Condition Register AND
Preliminary User’s Manual
crand
Condition Register AND
CR
BT
← CR
BA
∧ CR
BB
The CR bit specified by the BA field is ANDed with the CR bit specified by the BB field; the result is placed into the
CR bit specified by the BT field.
Registers Altered
•CR
Invalid Instruction Forms
• Reserved fields
Architecture Note
This instruction is part of the PowerPC User Instruction Set Architecture.
crand BT, BA, BB
19 BT BA BB 257
0 6 11 16 21 31