AMCC Proprietary 196
Revision 1.02 - September 10, 2007
PPC405 Processor
crnand
Condition Register NAND
Preliminary User’s Manual
crnand
Condition Register NAND
CR
BT
←¬(CR
BA
∧ CR
BB
)
The CR bit specified by the BA field is ANDed with the CR bit specified by the BB field; the ones complement of the
result is placed into the CR bit specified by the BT field.
Registers Altered
•CR
Invalid Instruction Forms
• Reserved fields
Architecture Note
This instruction is part of the PowerPC User Instruction Set Architecture.
crnand BT, BA, BB
19 BT BA BB 225
0 6 11 16 21 31