EasyManua.ls Logo

D-Link xStack DGS-3120 Series - Page 178

D-Link xStack DGS-3120 Series
1150 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
xStack
®
DGS-3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide
173
Format
config bpdu_protection [trap | log] [none | attack_detected | attack_cleared | both]
Parameters
trap - To specify the trap state.
log - To specify the log state.
none - Neither attack_detected nor attack_cleared is trapped or logged.
attack_detected - Events will be logged or trapped when the BPDU attacks is detected.
attack_cleared - Events will be logged or trapped when the BPDU attacks is cleared.
both - The events of attack_detected and attack_cleared shall be trapped or logged.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To config the bpdu_protection trap state as both for the entire switch:
DGS-3120-24TC:admin#config bpdu_protection trap both
Command: config bpdu_protection trap both
Success.
DGS-3120-24TC:admin#
13-4 enable bpdu_protection
Description
This command is used to enable BPDU protection function globally for the Switch.
Format
enable bpdu_protection
Parameters
None.
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To enable bpdu_protection function globally for the entire switch:

Table of Contents