xStack
®
DGS-3120 Series Layer 3 Managed Gigabit Ethernet Switch CLI Reference Guide
175
Restrictions
None.
Example
To show the bpdu_protection for the entire switch:
Command: show bpdu_protection
BPDU Protection Global Settings
----------------------------------------
BPDU Protection Status : Enabled
BPDU Protection Recover Time : 120 seconds
BPDU Protection Trap Status : Both
BPDU Protection Log Status : Both
Command: show bpdu_protection ports 1:1-1:12
Port State Mode Status
------ ----------- ---------- ----------
1:1 Enabled Drop Normal
1:2 Disabled Shutdown Normal
1:3 Disabled Shutdown Normal
1:4 Disabled Shutdown Normal
1:5 Disabled Shutdown Normal
1:6 Disabled Shutdown Normal
1:7 Disabled Shutdown Normal
1:8 Disabled Shutdown Normal
1:9 Disabled Shutdown Normal
1:10 Disabled Shutdown Normal
1:11 Disabled Shutdown Normal
1:12 Disabled Shutdown Normal