245
DGS-3120-24TC:admin# debug error_log dump
Command: debug error_log dump
**************************************************************************
# debug log: 1
# level: fatal
# clock: 10000ms
# time : 2009/03/11 13:00:00
====================== SOFTWARE FATAL ERROR =======================
Invalid mutex handle : 806D6480
Current TASK : bcmARL.0
------------------------- TASK STACKTRACE ------------------------
->802ACE98
->8018C814
->8028FF44
->8028352C
->801D703C
->8013B8A4
->802AE754
->802A5E0C
To clear the error log:
DGS-3120-24TC:admin# debug error_log clear
Command: debug error_log clear
Success.
DGS-3120-24TC:admin#
To upload the error log to TFTP server:
DGS-3120-24TC:admin# debug error_log upload_toTFTP 10.0.0.90 debug-log.txt
Command: debug error_log upload_toTFTP 10.0.0.90 debug-log.txt
Connecting to server................Done.
Upload error log ..................Done.
DGS-3120-24TC:admin#
22-2 debug show error_reboot state
Description
This command is used to display the error reboot status.
Format
debug show error_reboot state