104 01-6203-01R3, CG Drives & Automation
Manual loading of the OEM data via device command
Device command: "Load OEM data" 0x2022:005 (P700.05)
If the OEM memory contains invalid parameter settings, the user parameter settings
are loaded automatically.
If the OEM memory is empty, the status feedback "Action cancelled" takes place. The
current parameter settings remain unchanged.
Manual saving of the parameter settings via device command
Device command: "Save user data" 0x2022:003 (P700.03)
It may happen that the parameter settings cannot be saved because the user memory
is full. In this case, the following error message appears:
Error message
Infot
0x7680: Memory
module is full
The memory module contains too many parameter settings. The inverter copies the current backup to the user memory
without overwriting the data in the RAM.
Remedy: Execute device command "Save user data" 0x2022:003 (P700.03) again. This reinitialises the user memory with
the current parameter settings. By this means, parameter settings no longer required are deleted automatically.