13.1.4. Environmental conditions
Energy efficiency
Class IE2
EN 50598-2
Reference: Factory setting (switching frequency 8 kHz variable)
Climate
1K3 (-25 ... +60 °C)
EN 60721-3-1
Storage
2K3 (-25 ... +70 °C)
EN 60721-3-2
Transport
3K3 (-10 ... +55 °C)
EN 60721-3-3
operation
Operation at a switching frequency of 2 or 4 kHz: above +45°C,
reduce rated output current by 2.5 %/°C
Operation at a switching frequency of 8 or 16 kHz: above +40°C,
reduce rated output current by 2.5 %/°C
Site altitude
0 … 1000 m a.m.s.l.
1000 … 4000 m a.m.s.l.
Reduce rated output current by 5 %/1000 m
Pollution
Degree of pollution 2
EN 61800-5-1
Vibration resistance
Transport
2M2 (sine, shock)
EN 60721-3-2
operation
Amplitude 1 mm
Germanischer Lloyd
5 ... 13.2 Hz
Amplitude 0.075 mm
EN 61800-5-1
10 ... 57 Hz
13.1.5. Electrical supply conditions
Permissible mains systems
TT
Voltage to earth/ground: max. 300 V
TN
IT
Apply the measures described for IT systems!
IT systems are not relevant for UL-approved systems