464 01-6203-01R3, CG Drives & Automation
13.2. 1-phase mains connection 230/240 V
13.2.1. Rated data
The output currents apply to these operating conditions:
At a switching frequency of 2 kHz or 4 kHz: Max. ambient temperature 45°C.
At a switching frequency of 8 kHz or 16 kHz: Max. ambient temperature 40 °C.
Inverter
VS10-23-1P7 VS10-23-2P4 VS10-23-3P2 VS10-23-4P2 VS10-23-6P0 VS10-23-7P0 VS10-23-9P6
Rated power
kW
0.25
0.37
0.55
0.75
1.1
1.5
2.2
Mains voltage range
1/N/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Rated mains current
without mains choke
A
4
5.7
7.6
10
14.3
16.7
22.5
with mains choke
A
3.6
4.8
7.1
8.8
11.9
13.9
16.9
Apparent output power
kVA
0.6
0.9
1.2
1.6
2.2
2.6
3.6
Output current
2 kHz
A
-
-
3.2
4.2
6
7
9.6
4 kHz
A
1.7
2.4
3.2
4.2
6
7
9.6
8 kHz
A
1.7
2.4
3.2
4.2
6
7
9.6
16 kHz
A
1.1
1.6
2.1
2.8
4
4.7
6.4
Power loss
4 kHz
W
15
18
23
29
37
43
60
8 kHz
W
15
20
25
33
42
50
70
at controller inhibit
W
6
6
6
6
6
6
6
Overcurrent cycle 180 s
Max. output current
A
2.6
3.6
4.8
6.3
9
10.5
14.4
Overload time
s
60
60
60
60
60
60
60
Recovery time
s
120
120
120
120
120
120
120
Max. output current during the
recovery time
A
1.3 1.8 2.4 3.2 4.5 5.3 7.2
Overcurrent cycle 15 s
Max. output current
A
3.4
4.8
6.4
8.4
12
14
19.2
Overload time
s
3
3
3
3
3
3
3
Recovery time
s
12
12
12
12
12
12
12
Max. output current during the
recovery time
A
1.3 1.8 2.4 3.2 4.5 5.3 7.2
Cyclic mains switching
3 times per minute
Max. motor cable length shielded
without EMC category
m
50
Category C2
m
15
20
Weight
kg
0.75
0.95
1.35

Table of Contents