OEM memory
The OEM memory is provided for the storage of customised parameter settings by the
OEM/ mechanical engineer. If the user carries out parameter settings with the keypad,
they are always saved in the user memory if the keypad Enter key is clicked longer than 3
s. The OEM memory remains unaffected by these changes.
With the "Load OEM data" device command, the parameter settings preconfigured by
the OEM/mechanical engineer can be reloaded to the RAM memory of the inverter
anytime, if required.
For saving parameter settings in the OEM memory, the "Save OEM data" device
command
must be executed explicitly. The parameter settings are simultaneously
saved in the user memory.