Loading...
Inverter
VS30-40-7P3
VS30-40-9P5
VS30-40-013
VS30-40-016
Rated power
kW
3
4
5.5
7.5
Mains voltage range
3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Rated mains current
without mains choke
A
9.6
12.5
17.2
20
with mains choke
A
6.9
9
12.4
15.7
Apparent output power
kVA
4.9
6.4
8.7
11
Output current
2 kHz
A
7.3
9.5
13
16.5
4 kHz
A
7.3
9.5
13
16.5
8 kHz
A
7.3
9.5
13
16.5
16 kHz
A
4.9
6.3
8.7
11
Power loss
4 kHz
W
85
110
145
185
8 kHz
W
110
140
190
240
at controller inhibit
W
6
6
6
6
Overcurrent cycle 180 s
Max. output current
A
11
14.3
19.5
24.8
Overload time
s
60
60
60
60
Recovery time
s
120 120 120 120
Max. output current during the recovery
time
A
5.5 7.1 9.8 12.4
Overcurrent cycle 15 s
Max. output current
A
14.6
19
26
33
Overload time
s
3
3
3
3
Recovery time
s
12
12
12
12
Max. output current during the recovery
time
A
5.5 7.1 9.8 12.4
Cyclic mains switching
3 times per minute
Brake chopper
Max. output current
A
9.5
16.6
16.6
29
Min. brake resistance
Ω
82
47
47
27
Max. motor cable length shielded
without EMC category
m
-
-
50
100
Category C1 (2 kHz, 4 kHz, 8 kHz)
m
-
-
Category C2
m
20
Weight
kg
2.3
3.7

Table of Contents