EasyManua.ls Logo

Epson EPL-N3000 - Main Motor

Epson EPL-N3000
477 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON EPL-N3000/AcuLaser M4000N Revision C
Troubleshooting Troubleshooting for Individual Units 112
Confidential
3.4.2 MAIN MOTOR
Table 3-61. Troubleshooting for MAIN MOTOR
Step Action and Question Yes No
Parts below can be the source of this error (Chapter 4 Disassembly and Assembly)
MAIN MOTOR (p.279)
HARNESS ASSY LVPS
•LVPS (p.287)
•HVPS/MCU (p.301)
1
MAIN Motor
1. Remove the Imaging Cartridge.
2. Close the COVER OPEN.
3. Turn on the main power.
4. Check for operating sound of the MAIN Motor.
Does the MAIN Motor operate?
Go to Step 2 Go to Step 3
2
Has the trouble been cleared? Problem
solved
Go to Step 3
3
HARNESS ASSY LVPS (1)
1. Remove the SHIELD PLATE LVPS. (p.285)
2. Disconnect P/J41 from the LVPS.
(Refer to “Connectors (p.406)”)
3. Disconnect P/J11 from the HVPS/MCU.
4. Check continuity between P/J41 P/J11.
Is there continuity in each wiring between P/J41
P/J11?
Go to Step 4
Replace the
HARNESS
ASSY LVPS
4
HARNESS ASSY LVPS (2)
1. Remove the SHIELD PLATE LVPS. (p.285)
2. Disconnect P/J42 from the LVPS.
(Refer to “Connectors (p.406)”)
3. Disconnect P/J10 from the HVPS/MCU.
4. Check continuity between P/J42 P/J10.
Is there continuity in each wiring between P/J42
P/J10?
Go to Step 5
Replace the
HARNESS
ASSY LVPS
5
LVPS
1. Replace the LVPS. (p.287)
Has the trouble been cleared?
Problem
solved
Go to Step 6
6
HVPS/MCU
1. Replace the HVPS/MCU. (p.301)
Has the trouble been cleared?
Problem
solved
Replace the
MAIN
MOTOR
Table 3-61. Troubleshooting for MAIN MOTOR (continued)
Step Action and Question Yes No