EasyManua.ls Logo

Epson EPL-N3000 - FAN Error

Epson EPL-N3000
477 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON EPL-N3000/AcuLaser M4000N Revision C
Troubleshooting Troubleshooting When There is Error Display 74
Confidential
3.2.4 FAN Error
Table 3-7. Troubleshooting for “FAN Error”
Step Action and Question Yes No
Parts below can be the source of this error (Chapter 4 Disassembly and Assembly)
FAN MAIN (p.293)
•FAN SUB (p.241)
LVP S (p.287)
HVPS/MCU (p.301)
1
FAN MAIN
Does the Fan operate when the main power is turned
on?
Go to Step 2 Go to Step 3
2
Operation of FAN SUB
Does the FAN SUB operate when power is switched
on?
Go to Step 3 Go to Step 7
3
Power supply to FAN MAIN
Is the FAN MAIN connected correctly and is the
voltage between P/J24-18
P/J24-17 24 VDC (12
VDC at a half speed)?
Go to Step 4 Go to Step 5
4
FAN ALARM signal
Is the voltage between P/J24-17 P/J24-16 0.82
VDC or more?
Replace FAN
MAIN
Replace the
HVPS/MCU
5
FAN MAIN
1. Replace the FAN MAIN. (p.293)
Does the FAN error occur when power is switched
on?
Go to Step 6
Problem
solved
6
LVPS
1. Replace the LVPS. (p.287)
Does the FAN error occur when power is switched
on?
Replace the
HVPS/MCU
Problem
solved
7
Power supply to FAN SUB
Is the FAN SUB connected correctly and is the
voltage between P/J27-19 P/J27-18 24 VDC (12
VDC at a half speed)?
Go to Step 8 Go to Step 9
8
FAN ALARM signal
Is the voltage between P/J27-18 P/J27-17 0.82
VDC or more?
Replace FAN
SUB
Replace the
HVPS/MCU
9
FAN SUB
1. Replace the FAN SUB. (p.241)
Does the FAN error occur when power is switched
on?
Go to Step 10
Problem
solved
10
LVPS
1. Replace the LVPS. (p.287)
Does the FAN error occur when power is switched
on?
Replace the
HVPS/MCU
Problem
solved
Table 3-7. Troubleshooting for “FAN Error”