EPSON EPL-N3000/AcuLaser M4000N Revision C
Disassembly and Assembly 550 Paper Cassette 192
Confidential
4.4.2 RACK SIZE
Removal
1. Remove the COVER CST from the cassette body.
2. Unlock the LOCK EXTENSION, and draw out the cassette extension.
3. Release the hook fastening the GEAR PINION, and remove the GEAR PINION
from the HOUSING TOP 550.
4. While pushing the lock of the STOPPER GEAR, unlock the LEVER BTM LOCK,
and raise the PLATE ASSY BTM.
(p.200)
5. Move the GUIDE ASSY SD L550 to the inside, push down the hook of the
HOUSING TOP 550, and remove it from the HOUSING TOP 550.
6. Move the GUIDE ASSY SD R550 to the inside, push down the hook of the
HOUSING TOP 550, and remove it from the HOUSING TOP 550.
Figure 4- 25. RACK SIZE Removal
GUIDE ASSY SD L550
GUIDE ASSY SD R550
GEAR PINION
HOOK
HOOK
JG3132AA
HOOKS
CLAWS
HOUSING TOP 550
HOOK
PLATE ASSY BTM
GUIDE ASSY SD L550
WHEN ASSEMBLING
CLAW
HOUSING TOP550
CLAWS
3)
(NOTE 4)
5)
6)
(NOTE 3)