Chapter 5 Configuring the Meter
Configure – Measure Tab
DSAM Help User Guide Rev. 001 75
Renaming a TPC Plan
To rename a TPC plan
1 Using the arrow keys, select the TPC plan you want to rename.
2 Press the File softkey.
3 Using the arrow keys, select Rename.
4 Press ENTER.
Table 28 TPC Plan Parameters
Name Description
Forward External
Loss
Example: A distribution tap value on a drop. The
valid range is -50.0 to 50.0 dB. The default value is
0.0 dB.
Forward Probe
Loss
Example: Attenuator added inline with test lead.
The valid range is -50.0 to 50.0 dB. The default
value is 0.0 dB.
Reverse Internal
Loss
Example: Attenuation pad within an amplifier under
test. The sum of the internal, external and probe
losses plus the Telemetry level must be greater than
or equal to 10 dBmV. The default value is 0.0 dB.
Reverse External
Loss
Example: A distribution tap value on a drop. The
sum of the internal, external and probe losses
plus the Telemetry level must be greater than
or equal to 10 dBmV. The default value is 0.0
dB.
Reverse Probe
Loss
Example: Attenuator added inline with test lead.
The sum of the internal, external and probe losses
plus the Telemetry level must be greater than or
equal to 10 dBmV. The default value is 0.0 dB.
Reverse Teleme-
try Level
The sum of the internal, external and probe losses
plus the Telemetry level must be greater than or
equal to 10 dBmV. The default value is 20 dBmV.
Reverse Sweep
Insertion Level
The sum of the internal, external and probe losses
plus the Telemetry level must be greater than or
equal to 10 dBmV. The default value is 20 dBmV.
NOTE
If the TPC plan is set to Off, the Rename option is disabled.
21128026 R001 DSAM Help User Guide.book Page 75 Thursday, February 5, 2009 2:02 PM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JDS Uniphase DSAM-3600 and is the answer not in the manual?

JDS Uniphase DSAM-3600 Specifications

General IconGeneral
BrandJDS Uniphase
ModelDSAM-3600
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals