Chapter 9 Measure Mode – Service Tab
Ethernet
230 DSAM Help User Guide Rev. 001
15 Press ENTER.
16 Press the Start softkey.
When a ping test starts, response results begin scrolling upward in
the response box (upper right corner of the screen). The most
recent ping result is displayed at the bottom of the list.
The status box (in the lower right corner of the screen) displays
the reply statistics, including:
Number of pings sent
Average return time
Number of pings lost
Ratio of lost to sent pings
Ping data is continuously updated.
Restoring Ping Test
Defaults
To restore the default values for Packet Size and Time Between Pings.
Figure 206 Measure Mode – Ethernet Ping Test
Table 46 Ping Test Parameters
Name Description
IP Address Select from a list of up to ten of the most recently
used IP addresses.
Packet Size
(bytes)
Options are 64, 128, 256, 512, 1024, or 1518 (in
bytes). The default value is 64 bytes.
Time Between
Pings
Options are 0 ms, 10 ms, 25 ms, 50 ms, 100 ms, 1
sec, 2 sec, or 5 sec. The default value is 1 second.
21128026 R001 DSAM Help User Guide.book Page 230 Thursday, February 5, 2009 2:02 PM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the JDS Uniphase DSAM-3600 and is the answer not in the manual?

JDS Uniphase DSAM-3600 Specifications

General IconGeneral
BrandJDS Uniphase
ModelDSAM-3600
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals