Chapter 8 Measure Mode – Basic Tab
Hum Analysis
DSAM Help User Guide Rev. 001 191
3 Using the arrow keys, select Hum.
4 Press ENTER.
Understanding
Hum Analysis
Results
Figure 172 Measure Mode – Basic Tab: Hum
NOTE
If you chose the wrong limit set before conducting the test, press
the Limits softkey and select a different limit set to view your test
results in relation to a different limit set without rerunning the test.
Figure 173 Measure Mode – Hum Analysis
Frequency and
Frequency Hum
Total Hum for Bandwidth
Measurement
Information Area
NOTE
For information about how to read the graph, see “Reading Mea-
surement Graphs” on page 196.