Character string set in [S2] and read object (●: Read, Blank: Not read)
ALL
ALL +
Number
(1 to 16)
(Note 2)
NODE NORMAL STOP ERR PLC
Cyclic
communication
normal node table
(Note 3)
0 to 16
Cyclic
communication stop
node table
(Note 3)
0 to 16
Cyclic
communication
abnormal node table
(Note 3)
0 to 16
RUN/IDLE bit
monitor
(PLC standby flag)
(Note 3)
0 to 16
Read word count
(Note 1)
1 to 81 1 to 81 1 to 17 1 to 17 1 to 17 1 to 17 1 to 17
(Note 1) The number of read words varies according to the registered maximum node number.
Maximum node number Number of valid words
0 0
1 to 16 1
17 to 32 2
33 to 48 3
49 to 64 4
: :
225 to 239 15
241 to 256 16
(Note 2) When specifying "ALL + Number (1 to 16)" for [S2], the information for the number of effective words
that is specified by the "Number" is read.
(Note 3) The bits in the following table are allocated to the node table numbers and RUN/IDLE bit monitor.
Bit No.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Node
number
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
:
25
6
255
25
4
253 252
25
1
250 249
24
8
247
24
6
245 244
24
3
242 241
17.28 ETSTAT (Acquiring EtherNet/IP Information)