(3) Acquiring character string data from the offset position
[S1]... DT0 [S2]... H0 [D1]... DT100 [D2]... DT3000
S2: Acquired data format D1: Offset position D2: Acquired data storage
destination
Value Value Value
S2 0000H DT100
0007H
(Note 1)
DT3000 0000H
DT3001 0000H
Acquisition of the character string
data
(Note 1) The D1 offset position is updated to the start position of the 2nd data item when the CIPMGET
instruction is issued (2).
Operation result
S1: CIP message receive data D1: Offset position
Value Value
DT0 000DH DT100 0007H→000BH
DT1 00CBH D2: Acquired data
DT2
0000H
Acquiring data equivalent to the character
string length + 24 bytes
Value
DT3 0001H DT3000 0002H
DT4 02H
31H (1)
DT3001 ‘B‘ ‘A‘
DT5
41H (A)
00H
DT6 34H
42H (B)
DT7 ffH 12H
Offset position after updating
Value
DT0
DT1
1 0
CIP receive data
DT2
3 2
DT3 5 4
1st data
DT4 7
6
DT5
9
8
2nd data
DT6 B
A
DT7 D C
3rd data
17.34 CIPMGET (CIP Message Data Getting)
WUME-FP7CPUPGR-12 17-175

Table of Contents

Other manuals for Panasonic FP7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic FP7 Series and is the answer not in the manual?

Panasonic FP7 Series Specifications

General IconGeneral
BrandPanasonic
ModelFP7 Series
CategoryController
LanguageEnglish

Related product manuals