Editing and Deleting Users
To edit or delete a user you have created:
1.
Navigate to MANAGEMENT > NETWORK: SNMP Setup.
2.
Click the row of the SNMP V3 panel that displays the community you wish to edit or
delete. The cursor will change from an arrow icon to a pointing finger to indicate that
the entry is clickable.
3.
The SNMP V3 Settings window will display:
4.
Apply your changes and click Submit. OR: Click Delete to remove the User.
2.13.8.3 SNMP Traps
SNMP traps allow for automatic event notification, and as such are one way to remotely mon-
itor SecureSync's status.
SNMP traps indicate the status change that caused the trap to be sent and may also include one
or more objects, referred to as variable-bindings, or varbinds. A varbind provides a current
SecureSync data object that is related to the specific trap that was sent. For example, when a
Holdover trap is sent because SecureSync either entered or exited the Holdover mode, the trap
varbind will indicate that SecureSync is either currently in Holdover mode or not currently in
Holdover mode.
For testing purposes, a command line interface command is provided. This command,
testevent, allows one, several, or all of the traps defined in the SecureSync MIB to be gen-
erated. Refer to "CLICommands" on page513 for command details.
To define SNMP Traps (Notifications):
2.13 Configuring Network Settings
CHAPTER 2 SecureSync User Reference Guide Rev. 26
91

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)

Related product manuals